Bug 728 - NTP is going to disble state in LLB instance after the reboot ||CBI|| ||AS-12760||

Review Request #337 — Created July 15, 2024 and updated

timlai
APV10
rel_apv_10_7
728
tanya, weikai, wli

Root Cause:
In an HA bootup sync environment, starting ntpd returns non-zero for unknown reasons sometimes,
but the service is running fine, it cause we stop ntp service for error handling

Solution:
Add a workaround to check if ntpd is not running before handling the error.

Step to reproduce:
1. Setup HA on two APV
2. Enable ha bootup sync
3. Check ntp is on
3. Reboot one of APV
4. Once APV bootup, check ntp still on

Loading...