AE-257: In case of timeout the APV timer was taking 1 sec longer than configured

Review Request #623 — Created Jan. 17, 2025 and submitted — Latest diff uploaded

mmiriam
APV10
rel_apv_10_7, rel_apv_10_7_2
AE-257
phemadri, prajesh, tanya

APV is not handling the "http serverconnreuse timeout" as per set value. In case of timeout the APV timer was taking 1 sec longer than configured value which caused the server timeout before APV when APV forwarded request which caused a http error and reset.

build with change was tested in support lab during the test for jira 257